Abstract

We describe a technique to manage subluxated cataracts with the use of 4 or 5 disposable nylon iris hooks placed on the capsulorhexis edge to support the lens and stabilize the capsular bag during phacoemulsification. The use of an endocapsular tension ring provides excellent centration of the capsular bag, enabling endocapsular intraocular lens (IOL) implantation. Sixteen eyes with zonular dialysis between 90 degrees and 180 degrees had surgery with this technique. The mean visual acuity significantly improved from 0.26 ± 0.18 to 0.68 ± 0.33 ( P<.001). The surgeries were uneventful. Postoperative complications included cystoid macular edema 5 months after surgery in 1 eye and slight IOL dislocation with no symptoms detected 2 months after surgery in 4 eyes. The technique appears to be safe, ensuring a stable IOL with reduced surgical risks.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.