Abstract
BackgroundHere, the perspective of patients with primary and secondary immunodeficiency receiving subcutaneous immunoglobulin (SCIg) via introductory smaller size pre-filled syringes (PFS) or vials were compared.MethodsAn online survey was conducted in Canada by the Association des Patients Immunodéficients du Québec (APIQ) (10/2020–03/2021). Survey questions included: reasons for choosing SCIg packaging and administration methods, training experiences, infusion characteristics, and switching methods. The survey captured structured patient-reported outcomes: treatment satisfaction and its sub-domains, symptom state, general health perception, and physical and mental function. Respondents using PFS were compared with vial users, overall and stratified by their administration method (pump or manual push).ResultsOf the 132 total respondents, 66 respondents used vials, with 38 using a pump and 28 using manual push. PFS (5 and 10 mL sizes) were being used by 120 respondents, with 38 using a pump and 82 using manual push. PFS users were associated with a 17% lower median (interquartile range) SCIg dose (10 [8, 12] vs. 12 [9, 16] g/week, respectively), a significantly shorter infusion preparation time (15 [10, 20] vs. 15 [10, 30] mins, respectively), and a trend for shorter length of infusion (60 [35, 90] vs. 70 [48, 90] mins, respectively) compared with those on vials. Patient-reported treatment satisfaction scores were overall similar between vial and PFS users (including on the domains of effectiveness and convenience), except for a higher score for vials over PFS on the domain of global satisfaction (p=0.02).ConclusionsConsistent with prescribing that reflects a recognition of less wastage, PFS users were associated with a significantly lower SCIg dose compared with vial users. PFS users were also associated with shorter pre-infusion times, reflecting simpler administration mechanics compared with vial users. Higher global satisfaction with treatment among vial users compared with PFS users was consistent with users being limited to smaller PFS size options in Canada during the study period. Patient experience on PFS is expected to improve with the introduction of larger PFS sizes. Overall, treatment satisfaction for SCIg remains consistently high with the introduction of PFS packaging compared with vials.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.