Abstract
Subcooled flow boiling under high heat flux and high mass flux (HHHM) conditions is commonly encountered in nuclear power engineering, for example, the heat removal technology for divertors in the International Thermonuclear Experimental Reactor (ITER). In the present study, subcooled flow boiling heat transfer of water was carried out experimentally in a uniformly heated vertical circular tube with an inner diameter of 9.0mm under HHHM conditions. Heat transfer coefficients were presented from single-phase convection to fully developed nucleate boiling. The effects of parameters, including mass flux (G=6000, 8000, and 10,000kg/m2s), heat flux (q=5–12.5MW/m2), system pressure (P=3, 4.2, and 5MPa), and thermodynamic vapor quality (xth=−0.5 to −0.03), were discussed. Many previous heat transfer correlations available in the literature were assessed against our experimental data. Most of these correlations cannot predict the experimental data very well. A modified Chen correlation was developed, which predicted the total heat transfer coefficients with a mean average error of 1.11% and a root-mean-square error of 6.45%. A modified Lahey model was proposed to determine the contribution of nucleate boiling in the total heat transfer coefficient under HHHM conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.