Abstract
X-ray absorbers in the front ends and beamlines of synchrotron light sources are exposed to very high thermal loads. Many facilities, such as the Advanced Photon Source, are investigating upgrades that will further increase the thermal load. The likelihood of exceeding the limit of subcooled critical heat flux (CHF) in these components was examined. The assessment was performed for both currently possible off-normal operational conditions, such as might occur in the event of a failure of multiple safety interlocks, and the anticipated operating conditions that may result from future upgrades. The subcooled CHF values were calculated using empirical equations frequently cited in the literature and then compared with the computed values of the heat flux at the walls of the component cooling channels in cases where the cooling wall temperature exceeded the water saturation temperature at local hydraulic conditions. Having in mind that the great majority of the available empirical correlations were developed for the conditions characteristic for the operation of heat exchangers in the nuclear power industry, the limitations of this approach are discussed and an experimental study of the subcooled CHF values in the conditions similar to those expected in the front-end and beamline components is proposed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.