Abstract

To comprehend the most detrimental characteristics behind bone fractures, it is key to understand the material and tissue level strain limits and their relation to failure sites. The aim of this study was to investigate the three-dimensional strain distribution and its evolution during loading at the sub-trabecular level in trabecular bone tissue. Human cadaver trabecular bone samples were compressed in situ until failure, while imaging with high-resolution synchrotron radiation X-ray tomography. Digital volume correlation was used to determine the strains inside the trabeculae. Regions without emerging damage were compared to those about to crack. Local strains in close vicinity of developing cracks were higher than previously reported for a whole trabecular structure and similar to those reported for single isolated trabeculae. Early literature on bone fracture strain thresholds at the tissue level seem to underestimate the maximum strain magnitudes in trabecular bone. Furthermore, we found lower strain levels and a reduced ability to capture detailed crack-paths with increased image voxel size. This highlights the dependence between the observed strain levels and the voxel size and that high-resolution is needed to investigate behavior of individual trabeculae. Furthermore, low trabecular thickness appears to be one predictor of developing cracks. In summary, this study investigated the local strains in whole trabecular structure at sub-trabecular resolution in human bone and confirmed the high strain magnitudes reported for single trabeculae under loading and, importantly extends its translation to the whole trabecular structure.

Highlights

  • To comprehend the most detrimental characteristics behind bone fractures, it is key to understand the material and tissue level strain limits and their relation to failure sites

  • The distribution and evolution of strain magnitudes within the trabecular bone was assessed by digital volume correlation (DVC) between two consecutive image stacks

  • Throughout the loading, the average volumetric strains inside the crack regions were significantly greater from first DVC analysis step until yield point (Fig. 5a, b) compared to the non-crack regions. 95% confidence intervals (CI) of the difference between means varied from [0.6%, 1.5%] at early loading to [2.2%, 6.2%] at the yield point

Read more

Summary

Introduction

To comprehend the most detrimental characteristics behind bone fractures, it is key to understand the material and tissue level strain limits and their relation to failure sites. This study investigated the local strains in whole trabecular structure at sub-trabecular resolution in human bone and confirmed the high strain magnitudes reported for single trabeculae under loading and, importantly extends its translation to the whole trabecular structure. Earlier studies considering the structure of the trabecular bone network suggest that compressive loading causes global yielding at ~ 1 to 4% local tissue ­strain[10,11,12, 15]. These findings are largely based on finite element computational m­ odels[10,11,12], and plane 2D digital i­mages[15]. All the studies cited here report slightly different types of strains to describe yielding of trabecular bone (von Mises, maximum principal, tissue yield, ultimate strains) measured with different setups, the levels are reasonably consistent

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.