Abstract

We describe a cryogenic radiometric calibration system suitable for high sensitivity, low background power bolometers. The system uses a variable temperature blackbody source capable of temperatures of 4 to 20 K, whose output covers the sub-millimeter wavelength regime. The detector is an eight-channel, filled-focal-plane array of superconducting transition edge sensor (TES) bolometers. The system is designed to test components of the optical system such as polarizers, filters and stray light suppressors as well as the performance of the detector array elements. The bolometer response to incident submillimeter radiation is measured and compared to the calculated output of the source seen by the bolometer.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.