Abstract
BackgroundThis study examined whether measuring myocardial blood flow (MBF) in the sub-endocardial (SEN) and sub-epicardial (SEP) layers of the left ventricular myocardium using 13NH3 positron emission tomography (PET) and an automated procedure gives reasonable results in patients with known or suspected coronary artery disease (CAD). MethodsResting and stress 13NH3 dynamic PET were performed in 70 patients. Using ≥ 70% diameter stenosis in invasive coronary angiography (ICA) to identify significant CAD, we examined the diagnostic value of SEN- and SEP-MBF, and coronary flow reserve (CFR) vs. the corresponding conventional data averaged on the whole wall thickness. ResultsICA demonstrated 36 patients with significant CAD. Their global stress average [1.61 (1.26, 1.87) mL·min−1·g−1], SEN [1.39 (1.2, 1.59) mL·min−1·g−1] and SEP [1.22 (0.96, 1.44) mL·min−1·g−1] MBF were significantly lower than in the 34 no-CAD patients: 2.05 (1.76, 2.52), 1.72 (1.53, 1.89) and 1.46 (1.23, 1.89) mL·min−1·g−1, respectively, all P < .005. In the 60 CAD vs. the 150 non-CAD territories, stress average MBF was 1.52 (1.10, 1.83) vs. 2.06 (1.69, 2.48) mL·min−1·g−1, SEN-MBF 1.33 (1.02, 1.58) vs. 1.66 (1.35, 1.93) mL·min−1·g−1, and SEP-MBF 1.07 (0.80, 1.29) vs. 1.40 (1.12, 1.69) mL·min−1·g−1, respectively, all P < .05. Using receiver operating characteristics analysis for the presence of significant CAD, the areas under the curve (AUC) were all significant (P < .0001 vs. AUC = 0.5) and similar: stress average MBF = 0.79, SEN-MBF = 0.75, and SEP-MBF = 0.73. AUC was 0.77 for the average CFR, 0.75 for SEN, and 0.70 for SEP CFR. The stress transmural perfusion gradient (TPG) AUC (0.51) was not significant. However, stress TPG was significantly lower in segments subtended by totally occluded arteries vs. those subtended by sub-total stenoses: 1.10 (0.86, 1.33) vs. 1.24 (0.98, 1.56), respectively, P < .005. ConclusionAutomatic assessment of SEN- and SEP-MBF (and CFR) using 13NH3 PET gives reasonable results that are in good agreement with the conventional average whole wall thickness data. Further studies are needed to examine the utility of layer measurements such as in patients with hibernating myocardium or microvascular disease.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.