Abstract

Purpose: K-edge capture radiotherapy using monochromatic x-ray beams necessitates development of corresponding dosimetry techniques, one being utilization of Monte Carlo methods. Since Monte Carlo simulations yield dose per particle, a methodology to measure the beam fluence of a monochromatic synchrotron-generated x-ray beam was developed using Compton scattering techniques. Method and Materials: X-rays were produced at the LSU CAMD synchrotron by passing a 1.3-GeV electron beam (≈200 mA) through a 7-T superconducting wiggler. The resulting polychromatic beam passed through a double multilayer monochromator to generate a ∼0.1×2.8-cm2 beam. Since high fluence rates make direct measurement of beam fluence impossible, photons Compton scattered by thin polyethylene targets into a 1-mm thick × 2.54-cm diameter NaI(Tl) scintillation detector were counted. Incident beam fluence was calculated from net peak counts via application of the Klein-Nishina collisional cross section for polarized radiation at multiple scattering angles. Simultaneously, percent polarization of the beam was determined by separating the Klein-Nishina cross section into its two orthogonally-polarized components. Measurements were taken at 4 scattering angles (15°–60°) with the fraction of photons (f), polarized such that the angle between the direction of incident polarization and the scattering plane is 0°, determined by minimizing the standard deviation of the calculated fluences. Results: Incident beam fluence rates for 100 mA of synchrotron ring current were determined with ∼1% precision and ranged from to . Measurement showed that the 35-keV beam was highly polarized in the plane of the synchrotron, e.g. f =7%. Conclusion: We have demonstrated a feasible method based on Compton scattering to determine incident synchrotron-generated x-ray beam fluence and polarization. Fluences determined via this method can provide input data that will allow currently underway Monte Carlo simulations to predict dose distributions in homogeneous phantoms for comparison with more traditional dosimetry methods (ion chamber and radiochromic film).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.