Abstract
To validate the accuracy of ANSYS V.19, an experimental model based on a previous study was used to determine the typical values of crack pattern, ultimate load, and deflection. The model was a flat slab with an internal column with dimensions of 1000 × 1000 × 100 mm³. Four groups used a slab with an edge column in parametric research. The first group studied the opening size relative to the column face. The second group of specimens studied opening sizes close to column corners. The third group consisted of four specimens: two had openings in front of the column face and two in front of the column corner to study how opening distance affected flat slab behaviour. The fourth group examined the optimum opening arrangement in slabs with two openings around the column. The findings showed that flat slab openings at the column corner had higher ultimate load capacity than those at the column face; however, increasing opening dimensions beyond the column dimension decreases punching shear capacity. If the column needs two openings, place them on opposite faces or near the corners; this minimizes ultimate load reduction.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Engineering Research in Africa
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.