Abstract

In order to solve the problem of excessive vibration during the operation of the refrigeration unit in nuclear power plant, taking the double motor refrigeration unit in operation as the research object, we studied the effective measures to reduce the vibration and improve the stiffness of the double motors in the near resonance region. On the basis of theoretical calculation, the weaknesses of the equipment stiffness were reinforced and reconstructed, and the secondary analysis and calculation of the stiffness and seismic performance of the reformed refrigeration unit were carried out to determine the feasibility of the optimization scheme. Based on the analysis, we optimized the equipment. After that, there was a significant decrease in the vibration of the refrigeration unit. The vibration measurement results indicated that the vibration value of the unit has dropped to the qualified range, effectively avoiding the equipment damage caused by excessive vibration. We provided a complete set of analysis ideas for the research and solution of vibration problems of rotating equipment in nuclear power plant.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.