Abstract

Considering unit 3 in Zhanghewan pumped storage power station as the research object, transfer characteristics of pressure fluctuation at the vaneless area were studied from the dominant frequencies, the fractional amplitude and the fractional phase at four different measuring points. It was revealed that the variation trends of pressure fractional amplitude (50Hz and 100Hz) versus output agreed well at the four points, and the phase difference between the four points varied very small with increasing of output under different water heads. This research could provide instructive inspiration for solving the vibration problems in pumped storage power station, and provide useful thinking for optimizing hydraulic design of the pump-turbine.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.