Abstract

This paper mainly focuses on the research of the time-delay impact on electrical response of the proton exchange membrane fuel cell (PEMFC) system. Firstly, original static stack voltage and pressure models are proposed. Then, time-delay is discussed and analyzed. Thirdly, a time-delay mathematical model based on previous analysis is proposed and combined with the original model of PEMFC. After that, simulation on the whole PEMFC system with time-delay is setup by Matlab/Simulink using feedback linearization approach as its control strategy. Finally, the experiment is carried out for proving the validation of the proposed time-delay model of PEMFC, and similarities and differences between the simulation results and experiment are analyzed as well.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.