Abstract

BackgroundThe purpose of this study was to explore echocardiographic views and methods of aortic arch anomalies in infants, so as to improve the screening sensitivity and diagnostic accuracy.Methods140 children with abnormal aortic arch diagnosed by ultrasound in Children’s Hospital of Hebei Province from January 2014 to December 2019 were selected for retrospective analysis. All were confirmed by surgery or/and computerized tomography angiography. Series of views for aortic arch (the three-vessel and tracheal view, aortic arch short axis view, left aortic arch long axis view, aortic arch long axis continuous scan views) were performed in all cases on the basis of the routine views of echocardiography. The screening sensitivity and diagnostic coincidence rate of different echocardiographic views for aortic arch anomalies were analyzed.ResultsAmong the 140 infants, right aortic arch were 21 cases (6/21 were accompanied by mirror branch and 15/21 were with aberrant left subclavian artery). Left aortic arch with aberrant right subclavian artery were 2 cases, and double aortic arch with both arches open were 20 cases. Double aortic arch with left arch atresia were 2 cases, and atresia of the proximal aorta with aortic arch dysplasia was 1 case. Coarctation of the aorta were 67 cases, and interruption of aortic arch were 27 cases. All the patients were correctly diagnosed except that 2 infants with interruption of aortic arch were incorrectly diagnosed as coarctation of the aorta, and 1 infant with coarctation of the aorta was misdiagnosed as interruption of aortic arch by echocardiography. The screening sensitivities of four views and four-view combination for abnormal aortic arch were 99.3, 73.6, 87.1, 99.3, and 100%; the diagnostic coincidence rates were 85.7, 27.1,66.4, 95.0%, and 97.9% respectively. On the basis of traditional left aortic long axis view, other three views had their own advantages. The screening sensitivity and diagnostic coincidence rate of four-view combination were significantly improved.ConclusionsThe three-vessel trachea view is simple and feasible, which is suitable for screening abnormal aortic arch. The combination of four views conduces to improving screening sensitivity and diagnostic accuracy of aortic arch abnormalities.

Highlights

  • The purpose of this study was to explore echocardiographic views and methods of aortic arch anomalies in infants, so as to improve the screening sensitivity and diagnostic accuracy

  • We summarized the echocardiographic features of different types of aortic arch anomalies in each view, and compared ultrasonic diagnosis results with computerized tomography angiography (CTA) or/and

  • Diagnostic results of different types of aortic arch anomalies on different views by echocardiography One hundred forty infants with aortic arch anomalies were verified by CTA or/and surgery

Read more

Summary

Introduction

The purpose of this study was to explore echocardiographic views and methods of aortic arch anomalies in infants, so as to improve the screening sensitivity and diagnostic accuracy. The three-vessel and tracheal view is one of the internationally recognized important views for prenatal ultrasonic diagnosis of fetal congenital heart diseases [2, 3]. This view was applied to infants in this study for the first time, combining with series of views of aortic arch to diagnose and analyse aortic arch anomalies in infants. The objective of this study is to explore appropriate echocardiographic views and methods of aortic arch anomalies in infants and to improve the screening sensitivity and diagnostic accuracy

Objectives
Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.