Abstract
In the present paper, a chip with a Pt-based RTD that functions as a heater and sensor is tested under serial power loads, and infrared (IR) thermal imaging system is adopted to obtain the thermal measurement. Comparisons of the hotspot temperatures of the chip obtained by RTD and IR methods have been made, where different surfaces of the chip were observed by the IR camera. Combing with the heat conduction law, the IR results of the test chip with surface preparation showed quite a good agreement with the RTD data, verifying the validation of the IR analysis method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.