Abstract
This work is based on a typical RC frame that was closed to the epicenter and collapsed during the Wenchuan Earthquake. The seismic collapse resistance of the frame was strengthened by attached substructures, including conventional brace, buckling restrained brace (BRB) and viscous damper. Collapse fragility analysis based on incremental dynamic analysis is implemented for each strengthening scheme to compare their effects and to analyze the influence of critical parameters. The results show that the viscous damper performs better than the BRB, and the BRB performs better than the conventional brace. With the same strengthening parameters, the A-shaped bracing scheme is better than the X-shaped scheme.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.