Abstract

In order to study the seismic performance of fuxi miao’s congenital temple in Tianshui, we establish 3-D finite element model of the congenital temple in this paper. In the term of frequent earthquake and rare earthquake, Lanzhou wave and El-Centro wave and Taft wave are adopted to analyze the seismic response. It is shown the displacement reaction of the roof is largest, followed by Taft wave, and Lanzhou wave is smallest under El-Centro wave; The acceleration reaction of the roof is largest, followed by El-Centro wave, and Lanzhou wave is smallest under Taft wave. The displacement and acceleration maximum of the roof are slightly greater than that of the second floor, but are much greater than that of the first floor, thus the seismic response of the roof is the strongest. The acceleration peak of the nodes from the top of the first floor column to the roof increases very little, therefore it indicates the column base’s isolation and the friction energy dissipation of the mortise and tenon joint of beam and column make the congenital temple have good performance and shock absorption.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.