A pressure balance model for a circulating fluidized bed unit that incorporates a downer has been proposed. The model predictions were validated with the experimental data obtained from a special cold-model circulating fluidized bed. Comparison of the operation stability between a CFB downer and a CFB riser has been carried out. Only one critical gas velocity exists in the CFB-riser for a given riser solids flux, while there can be many critical gas velocities for the operation of a CFB downer. Therefore, it is possible to achieve high solids concentration in a CFB downer if appropriate operating conditions are used.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.