To investigate the thermal-hydraulic characteristics during natural circulation in an integral type marine reactor, basic single-phase natural circulation experiments were performed using scaled test facilities of the System-integrated Modular Advanced Reactor (SMART), and the RETRAN-03/INT code was developed. For both vertical and inclined conditions, the flow distribution through eight steam generator cassettes and thermal mixing in downcomer regions were observed. It was found that feedwater isolation does not enhance the asymmetric temperature distribution at the outlets of the steam generator cassettes. For inclined conditions, the results show typical flow characteristics according to the inclination angles. Flow rates in ascending steam generator cassettes increase by the increase in the thermal driving head, and consequently the outlet temperatures increase. Analytical and experimental results showed good agreements and it was concluded that RETRAN-03/INT is sufficiently capable of analyzing three-dimensional phenomena in an integral type reactor.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.