Abstract

The damage mechanism of a CCD detector was studied by building an experimental system containing a millisecond pulse laser irradiating a CCD detector. The experimental results show that the damage on the CCD detector was mainly thermal damage, along with mechanical damage. A melting phenomenon was caused by the thermal damage, so that a crater was observed on the surface of the CCD detector. Caused by melting of the polysilicon electrodes and a temperature rise in the silicon dioxide, the shift register impedance values were sharply reduced. Most of the substrate clock signals were broken and disappeared due to melting of channels in the silicon substrate layer, which caused a functional loss for the CCD detector. The mechanical damage on the melting edge of the CCD detector created heave; the temperature gradient caused this damage. In this paper, the decrease in vertical shift register impedance values was consistent with previous test results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.