Abstract

Abstract The presented work gives an overview on simulation and experimental results of the power supply parameters’ influence on DBD discharge uniformity. The proposed study is about the use of quasi-pulsed, power electronic power supply and a saturable inductor in series with the discharge cell [1]. The simulation results are presented with a parallel DBD reactor model with linear critical voltage distribution. A more uniform current waveform is observed, however, due to small reactor capacitances no streamer formation could be verified in calculations. An experimental test stand was prepared with a double dielectric barrier discharge arrangement. The experimental results are presented with regard to the electrical oscilloscope waveforms and ICCD camera imaging. A more homogenous plasma was observed in the case of saturable inductor with saturation current set at the point of discharge formation. Two possible mechanisms are connected with this phenomenon - inductive element current support during discharge and/or current rise-time limitation [1].

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.