Abstract

This paper presents a method to calculate the critical flow velocity of fluidelastic vibration of tube arrays in heat exchangers. The method is based upon the modal analysis technique, which combines the fluid dynamic force caused by cross flow and the vibration characteristics of the complicated tube array to obtain its response. The analytical method enables us not only to take into account the vibration mode of tube array and nonuniformity of velocity and density distribution of cross flow, but also to estimate the effect of antivibration devices, such as spacer, connecting band, and so on. Numerical examples of constrained single-tube array, multi-tube array in reversed flow, and group of panels with spacers are described.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.