Abstract

To investigate the fire performance of concrete-filled double-skin tubular (CFDST) columns with external stainless steel tubes, the fire resistance of this kind of composite members was analyzed by ABAQUS. The differences in the fire mechanisms between CFDST columns with external stainless steel tubes and those with external carbon steel tubes were studied. The effects of the cross-sectional dimension, hollow ratio, load ratio and material strength on the fire resistance of components were analyzed. The results show that the CFDST columns with external stainless steel tubes present better fire resistance than those with external carbon steel tubes. The fire resistance of members was greatly affected by the cross-sectional dimension and load ratio. The hollow ratio and material strength had a moderate influence on the fire resistance of the members. Based on a parametric analysis, a design method for the fire safety of CFDST columns with external stainless steel tubes was suggested.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.