Abstract
The calculation models of the equivalent convection coefficient between blast furnace gas flow and the hot surface of stave body, gas flow and in-laid brick were established by the combination of experiments and numerical calculation when the gas temperature is in the range of 505–1,248°C. The reason why the heat transfer coefficient between gas flow and in-laid brick is much more than that between gas and stave body was analyzed when the gas temperature is high. The opinion just to considering a kind of integration heat transfer coefficient while the numerical calculation of heat transfer model of stave will be changed. The division of above two heat transfer coefficients will increase the degree of heat transfer numerical calculation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.