Abstract
The air-fuel ratio (AFR) control becomes an important research direction in gas engine. This article conducts air-fuel ratio (AFR) closed loop control research in a CNG engine. The injection pulse width of gas is controlled by a controller, oxygen sensor signal as a feedback signal. In order to make the engine can achieve the anticipated air-fuel ratio under different conditions; we adopt fuzzy self-tuning PID control strategy based on feed forward control. We transformed a 2135G diesel engine into the single fuel gas engine. Experimental investigation on the effect of air-fuel ratio closed loop control .Experimental results shows that, fuzzy self-tuning PID control strategy can control CNG engine air-fuel ratio working in the good condition.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.