Abstract

To solve the problem of excessive dust concentration in the belt transportation roadway of the mine. Numerical simulations were used to study the dust migration in the belt transportation roadway under 1.5m/s ventilation conditions. The simulation results show the process of dust ejection from the inflow chute to contamination of the whole belt transportation roadway, and the spatial distribution of dust velocity. A comprehensive dust reduction scheme of "central suppression and bilateral splitting" was designed according to the dust distribution, with simultaneous control of the infeed chute and the roadway. In practical application, pneumatic spraying greatly reduces the amount of dust in the guide chute. The misting screen has a significant effect on dust collection and segregation. The solution effectively controls the dust in the space of 20m on both sides of the transfer point, and the dust removal efficiency reaches more than 90%.