Abstract

Charge-coupled device (CCD) cameras with liquid crystal tunable filters (LCTF) were introduced to capture the multispectral flame images for obtaining the line-of-sight radiation intensities. A least square QR decomposition method was applied to solve the reconstruction matrix equation and obtain the multi-wavelength local emission distributions from which temperature and volume fraction profiles can be retrieved. Compared with the original two-color method, the use of a wide range of spectral data was proved to be capable of reducing the reconstruction error. Reconstruction results of the two methods with different signal to noise ratio (SNR) were discussed. The effect of selected wavelength number is analyzed and the best number is determined to be in the range of 6–11. The proposed multispectral imaging system was verified to be feasible for the reconstruction of temperature and soot volume fraction distributions according to the experimental measurement results.