Abstract

Respiratory movement strongly affects the accuracy of stereotactic body radiation therapy (SBRT) of liver malignancies treated without the use of a respiratory gating system. This study investigates the feasibility and advantages of using a respiratory navigator-guided combined with patient breath-hold for liver SBRT in an adaptive magnetic-resonance guided workflow. Clinical datasets of 10 liver cancer patients treated with 1.5T MR-Linac with respiratory navigator-guided SBRT combined with patient breath-hold were retrospectively analyzed. All patients underwent simulation CT with and without contrast, and 4D-CT and 3D-T2w MRI without contrast. Patients received a prescription dose ranging from 36 to 50 Gy in 5 to 8 fractions and followed the adapt to shape (ATS) workflow including contours adjustment and a subsequent MR-based synthetic CT (sCT) calculation on the online MRI acquired. The reference treatment plan was optimized on the expiratory phase of the 4D-CT, and during the online session the contours and the adapted plans were performed using the 3D-T2w navigator MRI of the patient's end-expiratory signal; 2D-T2w real-time monitoring MRI was also used as support for the contour's definition. The radiation therapist instructed the patients to hold their breath at the end of the breathing cycle for the time of the beam on. A total of 59 fractions were analyzed. For each fraction the dosimetric parameters of the target and normal liver of the adaptive and reference plans were compared; particularly the volume, the conformity index (CI) and gradient index (GI) for the target, and V5, V10 and Dmean for the normal liver. T-student statistical analysis was performed; a p-value less than 0.05 was considered statistically significant. In the free breathing state, the 3D-T2w navigator MRI images enable a clear visualization of the tumor and its boundaries. The average target CI of the adaptive and reference plans is not significantly different (p = 0.448), while the GI is significantly higher (p = 0.043). Normal liver V10 and Dmean are lower and V5 is slightly increased, but without statistical differences. The mean values and standard deviation of the dosimetric parameters of the reference and adapted plans are shown in the Table below. The use of a respiratory navigator combined with the breath-hold for MRI- guided liver SBRT allows clear visualization of the tumor, ensures the accuracy of the delivered dose and may be considered an alternative when the respiratory gating system is not available during MRgART sessions.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call