Abstract

The metallic wire mesh is widely used in electromagnetic shielding engineering due to its obvious advantages such as light weight, high flexibility and low cost. The power cable joint uses metal mesh to restore the metal shielding layer. This paper studies the shielding effectiveness (SE) of metal mesh used for cable joint. Compare and analyze the shielding effectiveness of joint copper mesh and the effect of different specifications and double-layer copper mesh on the shielding effectiveness in terms of theoretical calculation and simulation. The results show that the shielding effectiveness of copper mesh varies with frequency; comparing different specifications of copper mesh, the shielding effectiveness of dense mesh is higher than that of sparse mesh; the shielding effectiveness of double-layer wire mesh is higher than that of single-layer wire mesh with the same specification when the distance between two-layer wire mesh is reasonably selected. Finally, the structure optimization scheme is proposed to improve the shielding effectiveness of cable joint copper mesh.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.