Abstract
This paper presents an assembly scheme of double bridge column-elevated subway stations. The scheme can help to realize the assembly construction of urban elevated subway stations. A 1/6-scaled precast assembly transverse frame of elevated subway station was designed and fabricated to verify the scheme. The pseudo-static loading test was performed to investigate the bearing capacity, failure mode and hysteretic behavior of the precast assembly transverse frame. Test results showed no joint connection failure occurred during the test, and the test specimen had good ductility, indicating that the assembly scheme proposed in this paper was feasible. Finally, the finite element model was established by calling PQ-Fiber subroutine developed by Tsinghua University with ABAQUS to study the seismic performance of test specimen. And numerical simulation results were in good agreement with test results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.