Abstract
In order to study the seismic response characteristics of long-span railway continuous girder bridges, located in the high seismic intensity regions. Take reasonable measures, to solve the seismic problem of fixed piers. This paper introducing a long-span railway continuous girder bridge as a research background, establishes a finite element model, nonlinear seismic response analysis of the whole bridge was carried, using the ductile seismic design method and the seismic isolation method. The parameters of the liquid viscous damper, and its influence on the damping effect are discussed. The results show that when using the ductility seismic design method, the structure relies on the plastic hinge hysteresis mechanism to dissipate the seismic energy, which may causes the large damage of the fixed pier. After damping design, the seismic design difficulty has been reduced. But to further solve the seismic problem, it is recommended that other seismic isolation devices be used simultaneously.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.