Abstract
Fuel vapor concentration is a key parameter for assessing the flammability of aircraft fuel tanks. However, the current research on RP-3 (Rocket Propellant-3) fuel vapor concentration is inadequate. This study categorizes fuel components by the number of carbon atoms and utilizes Raoult’s law to estimate the gas–liquid equilibrium relationship of each constituent element under equilibrium conditions. The equilibrium-state model is experimentally validated, and the differences in the constituents and fuel vapor concentrations of RP-3 and Jet-A (Jet Fuel-A) fuels are analyzed. In addition, an empirical correlation between the overall hydrocarbon concentration of RP-3 fuel vapor and the temperature and pressure in the equilibrium state is established, providing a theoretical basis for determining RP-3 fuel vapor concentration in related investigations. Furthermore, a transient prediction model of fuel vapor concentration is developed using the lumped parameter approach that considers the heat exchange among the fuel, gas, wall, and environment. The model’s accuracy is confirmed by comparing it to existing literature. Then, the temperature and fuel vapor concentration variation patterns in the fuel tank are calculated and evaluated under two typical flight scenarios. The results show a significant difference between the calculated fuel vapor concentration values obtained through equilibrium-state and transient models. Therefore, in the design of fuel vapor catalytic inerting systems, it is crucial to consider both the equilibrium and transient fuel vapor concentration values rather than relying solely on the former. Throughout the flight envelope, gas phase and fuel phase temperatures in RP-3, Jet-A, and C10H22 fuel tanks exhibit minimal differences. However, significant variations in fuel vapor concentration exist depending on the flight state and envelope. Hence, regarding RP-3 as equivalent to C10H22 is inappropriate. Additionally, fuel vapor concentration is a more suitable metric than fuel temperature for assessing fuel tank flammability.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.