Abstract
Pseudo static tests of 10 specimen made of 290 mm thick reinforced concrete masonry wall were finished, then test results were simulated by ABAQUS which use shell element, pamameters of the materials were defined by the comparison between the calculation results and that of the test. A 100 m high reinforced concrete masonry building in China was analyzed, elastic-plastic deformation check calculation under earthquake action by time-history analysis method were detailed. The story drift of the building is 1/666 for fortification intensity 6 and 1/326 for intensity 7 under strong earthquake, it is feasible.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.