Abstract

A research study has been undertaken to develop the fundamentals of a method for the direct dissolution of Metal Platinum. At room temperature and pressures, the reaction between sodium cyanide and platinum group metals (PGMs) does not occur because of poor kinetics. However, at elevated temperatures between 20°C and 180°C, PGMs can be dissolved by sodium cyanide like the reaction of gold. In this work, the dissolution of Platinum was measured in pressure clear cyanide solution. The data at different cyanide concentrations, different temperature and different oxygen pressure are obtained. With increasing cyanide concentration and oxygen pressure, the dissolution first increased to a maximum value and then decreased. With increasing temperature the dissolution is increased. The dissolution was found to have a relation of the cyanide and oxygen level. The dissolution was independent of rotation speed for oxygen-saturated solutions and cyanide concentrations above 5 mol.m-3 and was well below chemical reaction-limited for cyanide and oxygen.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.