Abstract

the effect of pH shock on the magnetic micro-aerobic activated sludge system used to deal with low load glucose wastewater was studied. After pH shocking under the condition of pH=6.0 and 9.0 for 15 days, CODCr removal efficiency of the reactor with magnetic powder was higher than that of the reactor without magnetic powder, and remained above 80% in the 5 days recovery experiment at pH=7.5, while about 50% of the reactor without magnetic powder. SVI in the reactor with magnetic powder was lower than that of the reactor without magnetic powder after pH shocking, and after the 5 days' recovery experiments, SVI of the sludge with magnetic powder could recovered to the original value, but the indicators of the sludge without magnetic powder could not recovered to the original value.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.