Abstract

The construction demand for irregular structures is increasing due to the population growth of cities, limited construction areas, and the aesthetics of structures. Lack of proper understanding on the dynamic behavior of these structures during seismic events can lead to local and global failures on them. In order to investigate this issue, we used a regular 10-story structure with three different stiffness irregularity cases along the elevation. Irregularities are considered in three positions: the lower half of the structure height, the lowest story, and the middle story. In this study, to reduce the damage and mitigate the seismic response of the structure, three control systems are proposed including a magnetorheological (MR) damper with semiactive fuzzy controller as the semiactive control system, a Tuned Mass Damper (TMD) as the passive control system, and the simultaneous use of them. Based on the numerical analyses under near- and far-field ground motions, the residual plastic deformations are significantly reduced by the simultaneous use of MR damper and TMD, while each of these dampers alone performs poorly in some cases. The results show that if these two dampers are used together, a more promising control system with robust performance against changes in system parameters can be achieved.

Highlights

  • Observing the behavior of irregular structures during the earthquake, this issue has been investigated by many researchers since 1970

  • Michalis et al [3] evaluated the behavior of vertically irregular structures using the Incremental Dynamic Analysis (IDA) method. e authors studied a 9-story steel frame known as LA9 by examining all four types of vertical irregularities: stiffness, strength, combined stiffness-strength, and mass irregularity. e results showed that the effects of vertical irregularity on the structural performance level depend on the type of irregularity, the story in which the irregularity occurs, and most importantly the severity of the

  • In order to control the vibrations of structures with stiffness irregularity, three different control systems incorporating MR damper, Tuned Mass Damper (TMD), and combined MR-TMD devices were proposed

Read more

Summary

Cape Mendocino

In these figures, 7 plots corresponding to earthquakes 1 to 7, according to Table 3 respectively from left to right, are presented.

Control strategy
Findings
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call