The operation control strategies of free-piston engine are investigated in this paper. To start the engine, it needs to adjust the compression pressure and the reset valves should cooperate with the frequency control valve to avoid squirm of the piston for hydraulic leakages. The reset valves should be closed before frequency control valve is opened. A piston position feedback modulation control method which can make sure the piston accelerated continuously is presented. It has fixed frequency control valves open signal moment but no fixed frequency control valves closed signal moment, and the closed signal was activated by piston position feedback.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.