Abstract
The design and fabrication of MEMS capacitive differential pressure sensor is reported. Silicon membrane is used as movable electrode. Gold metal film on glass is used as fixed electrode. Anodic bonding is used to bond together the silicon and glass to form the capacitive pressure sensor. The measurement capacitance of the sensors is 5.37 pF at an applied pressure of 0 kPa and 7.26 pF and the full operating range of 40 kPa.The ratio of changed to initial capacitance was 0.35. The error of the MEMS capacitive pressure sensor is less than 4‰ full-scale(FS) by using quadratic curve fitting which can meet most application requirements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.