Abstract

Because of its excellent insulation and arc extinguishing performance, Sulfur hexafluoride (SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> ) is widely used in electrical equipment such as gas insulated switchgear (GIS), circuit breakers, transformers. The detection of the components and contents of the decomposition products of SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> can provide an effective basis for the running state, abnormality or latent faults of SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> gas insulated electrical equipment in time. In order to ensure the accuracy and reliability of the results, this paper analyzed many cases in which SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> gas insulated electrical equipment were abnormal or broken-down in recent years, and made an in-depth study on multiple influence factors, such as sampling vessel material, sampling time, detection time, SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> decomposition products auto hydrolysis or be adsorbed by adsorbent and equipment structure. The results show that sampling by stainless steel bottles with fluorine coating, comprehensive investigation of the SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> gas decomposition products (such as SO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> F <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> , SOF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> ) that could characterize the fault, going to the scene as soon as possible or carrying out the inspection work through online device, fully considering the different detailed structure of electrical equipment are of important significance to improve the supervision level of SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> electrical equipment and achieve diagnosis and prediction when SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> electrical equipment gets fault.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.