Abstract
The relationships among solar radiation intensity, volume of heat storage tank, heating load and heat storage temperature difference has been revealed by the theoretical analysis on heat storage tank in active solar water heating system. Heat storage volume can be concluded with the simulation and analysis on solar water heating system in northwest area of China. And then, the nodal model of heat storage tank is simulated in different conditions with the help of CFD. The results show that the heat storage volume is diminished with increasing of heat storage temperature difference, and for practical project, the recommended values of heat storage volume in different cities are given. The lower water velocity at the inlet of heat storage tank is, the more obviously the layers are, and the recommended water velocity is between 0.01 and 0.05m/s.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.