Study about organic inhibitor has been performed to analyze effect of ginger extract concentration (Zingiber officinaler) to corrosion characteristic of API 5L grade steel under 3.5% NaCl and 0.1M HCl. Amount of 100 to 500 ppm inhibitor injected into each solution and electrochemistry tests were performed. Ginger extract has been prepared previously with maceration method and tested with FTIR to identify type compound in it. Tafel test result showed that corrosion rate of steel decreased in accordance with the increase of inhibitors concentration. Corrosion rate decreased to 12.13 mpy at 500 ppm inhibitor under NaCl solution, with efficiency 54.79%. While in HCl, corrosion rate showed similar trend, with corrosion rate 8.19 mpy at 500 ppm, with efficiency 81.66%. EIS result showed that impedance increased with the increase of inhibitors concentration, while FTIR result showed that ginger extract inhibitor contain 2-Methoxy-4-propylphenol which is known as antioxidant compound. According to XRD test, Fe2O3 and Fe3O4 compound were identified on steel surface. Ginger extract might worked better in acid environment since it decrease corrosion rate significantly compared to neutral solution.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.