Abstract

Open natural circulation systems are widely applied in the field of energy and chemical industries. Under some special conditions, open natural circulation systems with low height difference need to be applied, but research on this type of systems is not sufficient. In this paper, the flow modes of sucha natural circulation system were experimentally studied at low power level by adopting steam heating. In addition, the flow modes and physical phenomena of the natural circulation system were analyzed in detail under different heating power conditions. It is found that there are four flow modes at different power levels in the natural circulation system due to the influence of non-condensable gas and subcooled boiling. The inlet and outlet temperatures of heating section are analyzed in different flow modes. The result shows that the outlet temperature of heating section can be used as a judgment criterion for different flow modes.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.