Abstract

Flameless combustion has advantages such as low pollution and uniform temperature in the combustion chamber, making it an excellent option for heat exchangers. Previous studies have focused solely on the flameless combustion phenomenon, without considering its interaction with the target being heated. In this study, we conducted experimental and computational fluid analyses on a cylindrical reformer for reverse air injection flameless combustion. Typically, small-scale reformers of 10 kW or less are coaxial triple-tube cylindrical reformers. In contrast, multitubular reformers are used for larger-scale applications, since the heat transfer rate in single-burner cylindrical reformers decreases sharply as the scale increases. Flameless combustion, with high heat transfer efficiency, helps overcome the limitation of premixed burner. Compared with conventional premixed burners, flameless burner decreases the combustion gas outlet temperature by 30% at 25 kW while reducing energy consumption by 24% (owing to the high heat transfer rate) for a given cooling fluid outlet temperature. Furthermore, it is shown that introducing a ring at the combustion chamber exit can enhance combustion gas recirculation. The experimental result was confirmed through computational fluid analysis. It is concluded that for reverse air injection flameless combustion, the combustion gas recirculation rate in the combustion chamber is strongly related to the heat transfer.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call