Abstract

As one of the critical elements of fast linear transformer driver (FLTD), gas switch directly influences the output parameters, stability, and reliability of generators based on FLTD technology. In this paper, a multigap gas switch with six gaps in series has been investigated to study the proper firing conditions to get better performance for FLTD. The self-breakdown voltage with different gas pressure has been studied to derive the working ratio of the switch. The triggered breakdown delay and jitter with different charge voltage, gas pressure, and working ratio have been studied. The results indicate that when the switch is triggered by a 100-kV trigger voltage pulse under 180-kV charge voltage and 0.325-MPa pure nitrogen (70% working ratio), the delay time and the jitter are 34 and 1 ns, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.