Abstract
This paper presents effects of housing electricity and heat source equipments. We studied about energy saving effects of 4 equipments, CO2 Heat Pump water heater (CO2-HP), Micro Gas Engine Co-Generation System (GE-μCGS), Polymer Electrolyte Fuel Cell Co-Generation System (PEFC-CGS), and Solid Oxide Fuel Cell Co-Generation System (SOFC-CGS). As the result, we have found that energy consumption and CO2 emission reduction rate is the highest in case of SOFC-CGS. Energy consumption is reduced by 17-20% using SOFC-CGS on Electric Power Load Tracking Operation, and 44-47% on Rated Operation. And CO2 emission is reduced by 5-20% on Electric Power Load Tracking Operation and 22-46% on Rated Operation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Environmental Engineering (Transactions of AIJ)
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.