Abstract

Based on the piezoresistive function character and the conductivity of carbon fiber smart layer (CFSL), a novel electrical resistance tomography (ERT) system of spherical and cylindrical CFSL has been developed for global health monitoring. Based on the background of the third generation nuclear containment vessel, CFSL is stuck on the surface of the structure, and the effectiveness of the ERT system is verified by virtual experiment. The image reconstruction results show that CFSL on two-dimensional curved surface has good sensing characteristics in the complex strain state. Compared with structural volumetric strain in the monitoring area, it indicates that the high electrical resistance of CFSL is distributed in the high strain area of structures, and the low electrical resistance of CFSL is just distributed in the low strain area of structures. Therefore the resistivity’s distribution of CFSL can reflect qualitatively the structural volumetric strain field.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.