Abstract

To investigate efficient operating conditions for bipolar membrane electrodialysis (BMED), a comparison of current efficiency (CE) and power intensity (PI) was conducted using different anion-exchange membranes (AEMs) and salt solutions (NaCl and Na2SO4) as feed solutions in BMED. The results indicated that CE was higher and PI was lower for a commercial proton-blocking AEM (ACM) than for a standard AEM (ASE) when NaCl was used. This is because ASE has a higher water content than ACM, leading to greater H+ permeability, which reduces CE. Conversely, when Na2SO4 was used, ASE exhibited higher CE and lower cell voltage (CV) than ACM, resulting in lower PI for ASE. This is attributable to the fact that, with Na2SO4, the effect of CV was more significant than H+ permeability. These findings suggest that efficient operation can be achieved by selecting the appropriate combination of AEMs and salt solutions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.