Abstract
The EMC accordance in Power Electronics (PE) equipment depends more the character of the semiconductor devices who work as the switchers than in other electronic equipment because the switching of the semiconductor device in PE may be the main cause of EMI. This paper proposes a novel approach that acquires PE equipment signal waveform by an oscilloscope, and analyzes the signal with Continuous Wavelet Transform (CWT), which can diagnose device's characteristics effects on equipment EMI. The algorithms of proposed approach are given followed by a case study, proving the feasibility of the proposed approach.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.