Abstract
Under the speed-up on electric railways, overhead catenary systems on narrow-gauge lines have been improved with an increase of messenger wire tension. However, contact loss ratio of pantograph is comparatively high under the heavy simple catenary or feeder messenger wire type overhead catenary. These catenary has higher tension of messenger wire. In order to investigate into the causes and to work out effective improvement methods, laboratory and field tests have been carried out. From the results thereof, it is confirmed that contact force fluctuation comes under the influence of wave reflection factor at hanger, and a hanger which has spring mechanism is found effective to improve it. It is expected that rubber damping hanger or friction damping hanger contributes to reducing the contact loss of pantograph and the wear of contact wire.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.