Abstract

Use a 1000MW ultra-supercritical tower boiler as the research object. On the basis of one dimensional model, simplify the tube heat transfer model and the radiation heat transfer model; establish the two-dimensional area calculation model with the regional method; summarize the heat load distribution of flue gas temperature and water wall surface; and compare with the measured data. The error range of the result is acceptable on the project. The distribution of water wall surface heat load along the furnace width and the area where heat transfer deterioration cause easily along the furnace height direction are studied with the model and algorithm on different boiler load conditions. All these provide the reference for the design and operation of the ultra supercritical boiler.

Highlights

Read more

Summary

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.