Abstract

Canned motor pump is widely used in chemical industry. Due to the particularity of its application, it is necessary to ensure that the medium does not leak completely. If the axial force of impeller is too large, it will directly affect the performance of canned motor pump. Therefore, the floating impeller could be used in the pump to balance the axial force. In this paper, the relationship between axial clearance and leakage rate at the key part of canned motor pump is studied by means of numerical calculation and experimental verification. It is found that the fitting curve is highly consistent with the calculated value, which provided a good theoretical basis for further study of axial clearance control axial force and experimental axial force self-balance. In addition, the leakage rate increases with the increase of axial clearance. The static pressure in the axial clearance first increases and then decreases with the decrease of radius, and the maximum static pressure value is about 10.5% ∼ 15.8% near the clearance inlet. This study is of great significance to the theoretical research on the self-balance state of axial force of impeller.